Suspended Solids
Suspended solids and colloidal materials in feed water are one of the biggest
problems in reverse osmosis systems.
Even though most systems have some pretreatment including 5 micron prefilters,
these fine particles are responsible for fouling of reverse osmosis membranes.
In order to have some measure of the degree of this fouling problem, a
concept called Silt Density Index is used.
Here a 0.45 micron filter is exposed to the feed
water under pressure and filtration rates are calculated.
A detailed description of the test is available in our design
information section -
Click here to view the description.
An SDI of less than 5 is considered acceptable for the reverse osmosis
systems.
This means that at values of SDI of less than 5, the membranes should
foul at a very low rate.
Even though the concept works most of the time, there are
exceptions when a lower SDI (less than 3) is desirable due to the nature
of the suspended solids in that feed water. An SDI measurement kit is available and is shown on our website, http://www.appliedmembranes.com, in the “Products” section of our site - Click here to view the kit.
|